Switch card 230 VAC centralized
- For 230 VAC lamps
- 3 signal heads (9 supervised lamps)
- 2 potential-free outputs for controlling acknowledgement lamps for pedestrian buttons or coordination impulses for following systems, for example
- 4 potential-free inputs for pedestrian detectors, loop and public transport detectors or for system coordination, for example
- For insertion in the 19" switch card case
| Technical information: |
| Environmental conditions | -25°C...+60°C |
| Outputs signal head | 9 circuit breakers (230 VAC / each 5...50 W) on 3 channels (block, transient and enabling signals) |
| Additional outputs | 2 potential-free relay contacts with max. 230 VAC 6 A (cosφ = 1) or 1 A (cosφ = 0.6) |
| Detector inputs | 4 potential-free inputs, freely usable |
| Diagnosis | 9 colored LEDs: one per lamp output 1 LED: lamp voltage 1 LED: status of the switch module 1 LED: CAN activity |
| Addressing | Fixed over wiring, depends on slot |
| Installation | 19" plug-in card 6HU with front panel |
|